ESP-Modbus¶
Overview¶
The Modbus serial communication protocol is de facto standard protocol widely used to connect industrial electronic devices. Modbus allows communication among many devices connected to the same network, for example, a system that measures temperature and humidity and communicates the results to a computer. The Modbus protocol uses several types of data: Holding Registers, Input Registers, Coils (single bit output), Discrete Inputs. Versions of the Modbus protocol exist for serial port and for Ethernet and other protocols that support the Internet protocol suite. There are many variants of Modbus protocols, some of them are:
Modbus RTU
— This is used in serial communication and makes use of a compact, binary representation of the data for protocol communication. The RTU format follows the commands/data with a cyclic redundancy check checksum as an error check mechanism to ensure the reliability of data. Modbus RTU is the most common implementation available for Modbus. A Modbus RTU message must be transmitted continuously without inter-character hesitations. Modbus messages are framed (separated) by idle (silent) periods. The RS-485 interface communication is usually used for this type.Modbus ASCII
— This is used in serial communication and makes use of ASCII characters for protocol communication. The ASCII format uses a longitudinal redundancy check checksum. Modbus ASCII messages are framed by leading colon (“:”) and trailing newline (CR/LF).Modbus TCP/IP or Modbus TCP
— This is a Modbus variant used for communications over TCP/IP networks, connecting over port 502. It does not require a checksum calculation, as lower layers already provide checksum protection.
Modbus slave interface API overview¶
ESP-IDF supports Modbus slave protocol and provides modbus_controller interface API to interact with user application. The interface API functions below are used to setup and use Modbus slave stack from application and could be executed in next order:
The files deviceparams.c/h contain the user structures which represent Modbus parameters accessed by stack. These parameters should be prepared by user and be assigned to the modbus_controller interface using mbcontroller_set_descriptor()
API call before start of communication.
-
esp_err_t
mbcontroller_init
(void)¶ Initialize modbus controller and stack.
- Return
- ESP_OK Success
- ESP_FAIL Parameter error
The function initializes the Modbus controller interface and its active context (tasks, RTOS objects and other resources).
-
esp_err_t
mbcontroller_setup
(mb_communication_info_t comm_info)¶ Set Modbus communication parameters for the controller.
- Return
- ESP_OK Success
- ESP_ERR_INVALID_ARG Incorrect parameter data
- Parameters
comm_info
: Communication parameters structure.
The function is used to setup communication parameters of the Modbus stack. See the Modbus controller API documentation for more information.
-
esp_err_t
mbcontroller_set_descriptor
(mb_register_area_descriptor_t descr_data)¶ Set Modbus area descriptor.
- Return
- ESP_OK: The appropriate descriptor is set
- ESP_ERR_INVALID_ARG: The argument is incorrect
- Parameters
descr_data
: Modbus registers area descriptor structure
The function initializes Modbus communication descriptors for each type of Modbus register area (Holding Registers, Input Registers, Coils (single bit output), Discrete Inputs). Once areas are initialized and the mbcontroller_start()
API is called the Modbus stack can access the data in user data structures by request from master. See the mb_register_area_descriptor_t
for more information.
-
esp_err_t
mbcontroller_start
(void)¶ Start Modbus communication stack.
- Return
- ESP_OK Success
- ESP_ERR_INVALID_ARG Modbus stack start error
Modbus controller start function. Starts stack and interface and allows communication.
-
mb_event_group_t
mbcontroller_check_event
(mb_event_group_t group)¶ Wait for specific event on parameter change.
- Return
- mb_event_group_t event bits triggered
- Parameters
group
: Group event bit mask to wait for change
The blocking call to function waits for event specified in the input parameter as event mask. Once master access the parameter and event mask matches the parameter the application task will be unblocked and function will return ESP_OK. See the mb_event_group_t
for more information about Modbus event masks.
-
esp_err_t
mbcontroller_get_param_info
(mb_param_info_t *reg_info, uint32_t timeout)¶ Get parameter information.
- Return
- ESP_OK Success
- ESP_ERR_TIMEOUT Can not get data from parameter queue or queue overflow
- Parameters
reg_info
: parameter info structuretimeout
: Timeout in milliseconds to read information from parameter queue
The function gets information about accessed parameters from modbus controller event queue. The KConfig ‘CONFIG_MB_CONTROLLER_NOTIFY_QUEUE_SIZE’ key can be used to configure the notification queue size. The timeout parameter allows to specify timeout for waiting notification. The mb_param_info_t
structure contain information about accessed parameter.
-
esp_err_t
mbcontroller_destroy
(void)¶ Destroy Modbus controller and stack.
- Return
- ESP_OK Success
- ESP_FAIL Parameter error
This function stops Modbus communication stack and destroys controller interface.
There are some configuration parameters modbus_controller interface and Modbus stack can be configured using KConfig values in “Modbus configuration” menu. See the example application for more information about how to use these API functions.
Application Example¶
The example uses the FreeModbus library port for slave implementation: